The iris-fixated IOL is designed to correct myopia. Due to the larger optic, the Artisan 204 is recommended for patients who are prone to impaired night vision. The Artisan myopia is the first FDA-approved phakic IOL.
The iris-fixated IOL is designed to correct myopia. Due to the larger optic, the Artisan 204 is recommended for patients who are prone to impaired night vision. The Artisan myopia is the first FDA-approved phakic IOL.
The design of the Artisan 206 is based on the long-term experience of iris fixation. The Artisan concept has the longest design history of any iris-fixated IOL still in use today.
The Artisan 206 is designed for doctors seeking an IOL with a predictable, reliable, stable and versatile surgical procedure.
Artisan IOLs make your choices simpler. There is no need to make complicated decisions based on vaulting.
Material: | PMMA CQ-UV |
Overall Ø: | 8.5 mm |
Body Ø: | 6.0 mm | Convex-concave |
Dioptric Powers: |
-1.0 D to -15.5 D (0.5 increments) |
Merce Morral, MD, PhD, Jose L. Güell, MD, PhD, Mostafa A. El Husseiny, MD, Daniel Elies, MD, Oscar Gris, MD, PhD, Felicidad Manero, MD. J Cataract Refract Surg 2016; 42:117–126.
Silva RA, Jain A, Manche EE. Archives of Ophthalmology. 2008; 126(6):775-81.
Saxena R, Boekhoorn SS, Mulder PG, Noordzij B, Rij GV, Luyten GP. Ophthalmology. 2008; 115(4):608-13.
Meltendorf C; Cichocki M; Kohnen T. Ophthalmologica. 2008; 222 (2): 69-73.
Chen L-J, Chang Y-J, Kuo JC, Rajagopal R, Azar DT. J Cataract Refract Surgery. 2008; 34:1181-1200.
Neuhann IM, Neuhann TF, Heimann H, Schmickler S, Gerl RH, Foerster MH. J Cataract Refract Surgery. 2008; 34:1644-57.
Tahzib NG, Nuijts RM, Wu WY, Budo CJ. Ophthalmology. 2007; 114(6): 1133-42.
El-Raggal TM, Abdel Fattah AA. J Cataract Refract Surgery. 2007; 33(6): 966-70.
Benedetti S, Casamenti V, Benedetti M. J Cataract Refract Surgery.2007 ; May; 33(5): 784-90.
Tahzib NG, Bootsma SJ, Eggink FA, Nuijts RM. American J of Ophthalmology. 2006; 142(1): 31-39.
Ioannides A, Nartey I, Little BC. J Refract Surg. 2006; 22(1): 102-3.
Bootsma SJ, Tahzib NG, Eggink FA, de Brabander J. Nuijts, RM. J Refract Surg. 2006; 22(4): 367-71.
Tehrani M, Dick HB. J Refract Surg. 2006; 22(1): 96-8.
Senthil S, Prasad K, Ravisankar R, Srilakshmi. Indian J Ophthalmology. 2006; 54: 251-5.
Budo C, Bartels MC, Van Rij G. J Refract Surg. 2005; 21(3): 218-22.
Benedetti S, Casamenti V, Marcaccio L, Brogioni C, Assetto V. J Refract Surg. 2005 Mar-Apr;21(2):116-26.
Lombardo AJ, Hardten DR, McCulloch AG, Demarchi JL, Davis EA, Lindstrom RL. Ophthalmology. 2005 Feb;112(2):278-85.
Moshirfar M, Barsam CA, Parker JW. J Cataract Refract Surg. 2004 Jul;30(7):1578-81.
Lifshitz T, Levy J, Aizenman I, Klemperer I, Levinger S. Int Ophthalmol. 2004 Jul;25(4):233-8.
Pop M, Payette Y. Ophthalmology. 2004 Feb;111(2):309-17.
Güell JL, Morral M, Gris O, Gaytan J, Sisquella M, Manero F. Ophthalmology. 2008;115(6): 1002-12.
Stulting RD, John ME, Maloney R K, Kerry K. Assil, Peter N. Arrowsmith, Thompson V M. Ophthalmology .2008; 115:464-72.
Moshirfar M, Holz HA, Davis DK. J Cataract Refract Surgery. 2007; 33(8): 1392-7.
Camille Budo, Jean C. Hessloehl, Milan Izak, Gregorius P.M. Luyten, Jose L. Menezo, Bozkurt A. Sener, Marie José Tassignon, Herve Termote, Jan G.F. Worst
At Ophtec, we're here to help you. Leave your contact details with us and we'll get back to you as soon as possible.
We’ll help you make the right purchase.
Disclaimer: Not all products are available worldwide. Contact us to check availability.